Flux regeneration units are key equipment in a modern hot dip galvanizing plant. A balanced chemical composition in the flux tank is vital to high quality galvanizing. Normally, fluxes are polluted with iron ions that are dragged in from previous steps in the process. Iron is naturally bond to zinc so an abundance of iron in the flux will inevitably generate large amounts of undesired floating or bottom dross. It is therefore quite crucial to keep iron content in flux under control, avoiding expensive zinc waste in the form of dross
Features
- Easy to use and to maintain, even inexperienced operators will be able to handle them
- Stable operation
- High treatment efficiency
- Small size and light weight, simple structure
Components
- PLC
- Body
- Filter presses
- Peristaltic pump
- Pneumatic diaphragm pump
- Ammonia and hydrogen peroxide tank
- Mixing tank
Technical parameters
- Max processing capacity: 8-10m3/h
- Power: 14KW
- Control mode: PLC centralized control
Effect Analysis
- Adjust the proportion of acid, iron, ammonia and zinc in the flux tank to the best
- Recycling of the flux,achieve zero effluents
- Control the content of iron is under 1g/L, reduce the zinc consumption
- improve the fluidity of zinc liquid and surface quality of workpiece